RMS Pump, Inc.
Multnomah County PM
2610 Fairview Parkway
Fairview, OR 97024
(503) 665-8101
lmcquaw@rmspump.com
Multnomah County PM
Preventative Maintenance Record
Technician Notes
Running 70%. Volts/amps @80%. Noise pass (V).
Readings
| Reading | Point 1 | Point 2 | Point 3 | Point 4 | Point 5 | Point 6 | Point 7 | Point 8 |
|---|---|---|---|---|---|---|---|---|
| Mils | A.4-1.1 | B.3-.8 | C.16-.3 (V) | D.48-.92 | E.24-.72 | F.12-.54 | G.13-.2 | H |
| In/sec | A.08 | B.06 | C.08 | D.09 | E.06 | F.07 | G.11 | H |
| G's Peak | A1.1 | B.84 | C.94 | D.8 | E.54 | F.64 | G.75 | H |
| Temp | PT | PM72° | PB | MT87.2° | MM97.8° | MB106.5° | A | B |
| RPM at shaft | |
|---|---|
| Ambient Temp. | 71 (V)° |
| Amps | 10.1 / 9.0 / 9.8 |
| Volts | 475 / 478 / 477 |
| Meg (resistance) | |
| Hours (runtime) | |
| Inlet pressure | 63-76 (V) |
| Discharge pressure | 180-210 (V) |
| Noise | Pass |
| Controller Temp | 78-88 (V)° |
Pump Information
Goulds domestic booster system
Motor Information
Baldor
Controller Information
VFD
Valve Information
Suction and discharge valves